FEATURES OF TOWER STRUCTURE OBSERVATIONS
DOI:
https://doi.org/10.55640/Keywords:
tower-type structures, one-sided heating, structure curvature, curvature value, temperature fields, wind load, wind flow, solar heating, tower axis deviation.Abstract
This article analyzes the influence of external factors on the geometry of tower-type structures under construction and in operation. Based on this analysis, the need to develop a methodology for geodetic surveys that takes these influences into account is proposed.
Downloads
References
1. [1] Sytnik V.S., Klyushin A.B. Geodezichesky contral tochnosti vozvedeniya monolithic zdaniy i soorujeniy. M. Stroyizdat, 1981.
2. [2] John N. Hatropoulos. Topographic mapping. Universal publishers. Boce Raton, Florida. USA. 2008.
3. [3] Romanus T.N. Ob uchete deformatsiy jelezobetonnykh konstruktsiy iz-za neravnomernogo nagreva otdelnykh chastei zdaniya. Geodesy and cartography. 2003. #1. s. 24-27.
4. [4] Brickman G.A. Analysis of Ostankino tower body movements under the influence of the temperature factor Most and towers for Radio and television. Bratislava. 1991. Book-2. P.188-192.
5. [5] Avchiev Sh.K., Valieva AR. Analysis of geodetic methods of defining deformational characteristics of high-rise buildings and territories of Uzbekistan. Materialy 1 mejdunarodnoy nauchno-praktichesky conference. Fergana. 2019. 4 volumes. pp. 192-196.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors retain the copyright of their manuscripts, and all Open Access articles are disseminated under the terms of the Creative Commons Attribution License 4.0 (CC-BY), which licenses unrestricted use, distribution, and reproduction in any medium, provided that the original work is appropriately cited. The use of general descriptive names, trade names, trademarks, and so forth in this publication, even if not specifically identified, does not imply that these names are not protected by the relevant laws and regulations.